Kemerovo, st. 2nd Kamyshinskaya, building 3, building 2a, office one
EXPLOSION-PROOF FREQUENCY CONVERTER STATION of EPFCS type: UHL 5

EXPLOSION-PROOF FREQUENCY CONVERTER STATION of EPFCS type: UHL 5

EPFCS
-
Explosion-proof frequency-converter station
XXX
/
Nominal capacity of the station, KW
0,69
-
Rated voltage, V
UHLN
-
Climatic option according to GOST 15150-69

Specifications

Блок стилей "STYLE"
Parameter Meaning
1 Rated voltage of main circuits, V 660
2 Rated current, A 204, 403, 583
3 Supply frequency, Hz 50
4 Nominal station capacity, KVA 160, 320, 500
5 Power of connected electric motor for conveyor driving head, kW 80..500
6 Torque control adjustment of electric motor, % 0..100
7 Maximum developed motor shaft torque, % 150
8 Adjustment spin-rate control of electric motors, % 10..100
9 Powerof connected electric motors for electric driving motor cooling fans, kW
4
10
Powerof connected electro-hydro pushers for conveyor driving head, kW
1
11 Powerof connected additional equipment or lighting voltage 127/220 V, kW 1
12 Cooling method of frequency converters and rectifier Liquid
13 Explosion protection type PB Ex d [ia op is] IX
14 Protection level of jacket according to GOST 1515-69 IP 54
15 Weight, kg, no more than 2800
16 Overall dimensions, mm, not more (length, width, depth) 3200х785х1430

Complectation

The EPFCS UHLS5device is designed for stepless variable electric regulation of speed and torque of a single-motor drive and supply of voltageto all auxiliary devices of the station in gas and/or dust hazardous underground mine workings.

The device is made with spark-safe remote control circuits, it has explosion-proof design and protection marking PB Exdfialia I. The shell structure provides the adequate ingress IP54 protection according to GOST 14254-96.

The station is designed to operate in networks with isolated neutral.

It provides:

  • Stepless variable electric regulation of speed and torque;
  • operational local and remote control of electrical drive;
  • absence of sharpjerks and shocks;
  • mechanicaland electrical locking;
  • control of the auxiliary engines of brake cooling circuit, motor drives and other auxiliary equipment.

Electric motor protection:

  • data transfer via the RS-485 interface, Modbus protocol;
  • connection to fiber-optic communication line;
  • logging of the emergency events.

Operating conditions:

  • ambient air temperature +1...+35°C;
  • relative air humidity is up to 100% at temperature +35°C;
  • absence of sharp jerks and shocks;
  • dust condition of the ambient air is not exceeding 1000 mg/m3;
  • working position in the spaceis horizontal, the deviation from working position up to 15 degrees in any direction is allowed.

Reliability indicators:

  • average time between failures - min 8000 h;
  • established resource beforefirst major overhaul - min 65000 h;
  • average total servicelife - min 15 years;
  • mean time to recovery - no more than 2 hours.