FREQUENCY CONVERTER FOR VENTILATION FAN of FCVF type
FCVF
-
Frequency converter of ventilation fan
XX
/
Powerof frequency converter, kW
XXX
-
Supply voltage, V
UHL5
Climatic performance according to GOST 15150-69
Specifications
Основные технические параметры:
№, п/п | Параметр | Значение |
---|---|---|
1 | Numberof phases of supply mains | 3 |
2 | Rated voltage of supply system, V | 690 |
3 | Supply frequency, Hz | 50 |
4 | Number of connected Bf, pcs | 1 (2) |
5 | Total power of BF engines, KW | 50 /75 / 90 |
6 | Method of connecting power cables | БРС |
7 | Port capacity RS-485 | 2 |
8 | Communication protocol (field communication) | ModBUS RTU |
9 | Cooling method | air |
10 | Overall dimensions, mm, not more (length, width, depth) | 1120 х 1385 х 1000 |
11 | Weight in kg, no more than | 850 |
12 | Marking of explosion protection | РВ Ех d [ia ор is] l |
13 | Protection level of jacket according to GOST 14254, not lower than | IP 54 |
14 | Operating ambient air temperature value, C | -10 .. +45 |
Complectation
Frequency converter of ventilation fan of FCVF type is intended for automatic maintenance of specified booster fan (BF) capacity in networks of 690 V with frequency of 50 Hz at coal mining enterprises gas and/or dust hazardous.
The device is made with spark-safe remote control circuits, it has the explosion-proof design and protection marking PB Exd[ia]ia I. The shell structure provides ingress IP54 protection according to GOST 14254-96.
It provides:
- Operational localand remote control;
- possibility to connect two motors to one converter;
- operating or standby mode of drive operation;
- connection to main optical communication link;
- electrical protections* (27,50, 59, 79, etc.);
- preliminary insulation testing of outgoing lines (BRU mode);
- protection against loss of control;
- control of air leakage from the ventilation pipe;
- control of vibration accelerations of BF motor;
- protection against BF shaft seizure.
Operating conditions:
- Ambient air temperature -10...+35°C;
- relative air humidity up to 100% at temperature +35°C;
- absence of sharp jerks and shocks;
- dust content in ambient air is not more than 1000 mg/m3;
- working position in space is horizontal, deviation from
- the working position up to 15 degrees in any direction is allowed.
Reliability indicators:
- Average time between failures - not less than 8000 h;
- established resource beforefirst major overhaul - not less than 65000 h;
- average total service life - not less than 15 years;
- mean recovery time - no more than 2 hours.